Ultrapure Gas Delivery

Eliminating siloxane impurities from silane process gas using next-generation purification

Barry Gotlinsky and Joseph O'Sullivan, Pall; and Motonobu Horikoshi and Shinichi Babasaki, Nihon Pall

Parts-per-trillion-level purification of process gases can be obtained with a new purification technology and confirmed through APIMS measurements.

Silane and other process gases used for thin-film formation in semiconductor fabrication must be purified in order to eliminate contaminants that can lead to yield-inhibiting defects. One of the most difficult contaminants to control is moisture in silane gas, which can cause particle generation in tubing and chambers and can adversely affect the quality of thin films, which have become increasingly thinner with each process generation.

Filtration is a standard practice for maintaining the particulate cleanliness of process gases. In the case of anhydrous silane, particles are expunged by classical methods, ensuring removal of those particles generated upstream in the gas delivery lines. However, if moisture contaminates the gas, particles will form downstream of the filter because of silicon dioxide nuclei formation, which can be followed by nuclei condensing and particle formation. The clustering of siloxane molecules can also lead to particle formation.

In order to achieve gas purity at the low to single-digit parts-per-trillion level, an alternative purification approach is required. The Gaskleen PPT reactive filter technology developed jointly by the Sematech Center of Excellence at the University of Arizona (Tucson) and Pall (Port Washington, NY) is one such approach. Because the reactive sites are located on the stainless-steel filter medium, this next-generation filter is a true integrated purifier/filter (see Figure 1).1 The chemistry is an integral composite of intercalate reactive metal compounds in reduced form. These compounds become an integral part of the existing fibrous filter matrix, thus creating a true point-of-use purification surface. The use of a high-surface-area stainless-steel filter medium as the support structure for the reactive sites facilitates the removal of homogenous impurities by ensuring contact of the impurity with the reactive sites.

Figure 1: Schematic of the next-generation purifier.

The reactive filter is well suited for the purification of specialty hydride gases. The filter's efficacy in purifying silane gas is demonstrated by a quantitative reduction in siloxane peaks in the atmospheric pressure ionization mass spectroscopy (APIMS) spectrum of silane. The use of high-purity silane gas is essential to reduce silicon dioxide film thickness to the extent that 256-Mb and 1-Gb DRAM processes can be successfully developed. The recent introduction of a modified APIMS that can measure impurities in silane permits confirmation of the required purity levels.2­4 In conjunction with the modified APIMS for silane purity analysis, laser particle counters can be used to examine particle levels in the gas.

Experimental Data

A study that tested filters in nitrogen and silane, without purification, demonstrated that particles were found downstream of the filters validated for their performance in nitrogen.5 This study utilized a newly designed particle counter with 0.1-µm resolution, which could be used in situ with silane. A PTFE membrane filter used in nitrogen yielded <1 particle >0.1 µm per 100 ml of gas. When the gas was switched to silane, the filter yielded 22,000 particles >0.1 µm per 100 ml. The gas was switched upstream of the filter without disturbing any connections to the filter. An interesting observation was that without a filter, 1200 particles per 100 ml of silane gas were measured.

It is hypothesized that the increase in particles found downstream of the filter occurred because of increased collisions of siloxane molecules, formed from moisture in the gas reacting with silane, downstream of the filter membrane. The enhanced formation is caused by the increased turbulence of gas flow through the filter. Clustering of these molecules creates measurable-sized particles. Purification of the silane gas can eliminate this contamination by removing the moisture and siloxane before it can react with the silane. Figure 2 shows 0.1­0.2-µm particle counts on wafers detected with a surface scanner from KLA-Tencor (San Jose). The counts depicted in the figure were taken before and after the silane purification began. The wafers that were analyzed came from a low-pressure CVD process in a DRAM line at a major semiconductor manufacturer. As the figure illustrates, the particle counts on the wafer dramatically dropped with purification. These data corroborate the study's particle data and the hypothesis that particles were generated by the reaction of silane and moisture.

Figure 2: Wafer counts of 0.1–0.2-µm particles, with and without the purification of the silane gas.

The purifier's ability to deliver silane gas without siloxane impurities was demonstrated by another study on silane purification that used APIMS as the analytical method. The study was conducted from 1998 to 1999 at Tadahiro Ohmi's laboratory at Tohoku University in Sendai, Japan. The test setup, shown in Figure 3, consisted of a silane gas cylinder, moisture injection line, and argon carrier gas. The APIMS was modified to analyze silane by initially ionizing argon in the first chamber, then ionizing silane and its impurities in the second chamber.2­4 This eliminates interference by the argon, oxygen, nitrogen, hydrogen, and CH4 because of their high ionization potential.

Figure 3: Schematic of the APIMS test setup.

Figure 4 depicts the impurities found in the silane without purification and following 10-ppb water injection. Silane peaks are at a mass per charge of 31 and 63 (SiH3+ and SiH4-SiH3+, respectively). Moisture peaks are at a mass per charge of 49, 67, and 79 (H2O-SiH3+, 2H2O-SiH3+, and H2O-Si2H3+, respectively). Siloxane peaks are at a mass per charge of 77 and 109 (SiH3OSiH2+ and [SiH3]2O-SiH3+, respectively), while disilane peaks are at 61and 93 (Si2H5+ and SiH4-Si2H5+, respectively).

Figure 4: APIMS reading of silane impurities without purification.

When the silane gas with the 10-ppb water injection was passed through a purifier, the water and siloxane peaks were reduced. The purifier uses a chemically reactive resin-based material for parts-per-billion-level purification. A comparison of Figures 4 and 5 reveals decreases in the relative intensities of siloxane and water. When the same silane gas with 10-ppb moisture was further treated with the new purifier technology after the resin-based purifier, the siloxane and water peaks were essentially eliminated. These results suggest that additional purification of the gas helps reduce particle contamination and film defects to the levels needed for advanced devices. Figure 6 shows the benefits of the additional purification by illustrating the absence of the siloxane and water relative ion intensity peaks.

Figure 5: APIMS reading of silane impurities with resin-based purification.

Figure 6: APIMS reading of silane impurities with resin-based purification plus purification with the new method.

 

Conclusion

Semiconductor manufacturers continue to use conventional purification techniques for process gases with impurities in the low-parts-per-billion to high-parts-per-trillion range. However, the development of APIMS and the continuing demand for higher- purity gases in many applications has resulted in the need for purification to low-parts-per-trillion levels. A new purifier/filter's ability to achieve low-single-digit parts-per-trillion purity gas has enhanced the ability of APIMS to detect purity levels of <20 ppt for inert gases. In addition, purification to low-parts-per-trillion levels will ensure that film defects are reduced to the levels required for advanced devices and can be a significant aid in reducing the downtime of process equipment.

Acknowledgments

A version of this article was presented at the Workshop on Gas Distribution Systems at Semicon West in San Francisco in July 2000. Used with permission.

References

  1. Further technical information can be found at http://www. pall.com/micro.
  2. A Ohki et al., "High Purified Silane Gas for Advanced Silicon Semiconductor Device" (unpublished manuscript).
  3. Y Mitsui et al., "Development of a New APIMS for the Detection of Trace Impurities in Special Gases," in Proceedings of the 40th Annual Technical Meeting of the IES (Mount Prospect, IL: Institute of Environmental Sciences, 1994), 246­253.
  4. Y Mitsui et al., "Impurity Analysis in Specialty Gas Using APIMS with Bicompartment Ion Source," in Proceedings of the 28th Ultraclean Technology Workshop (Tokyo: Ultraclean Society), 27­33.
  5. K Ichijo et al., "Particle Measurement in Processing Gases and CVD Apparatus," in Proceedings of the 28th Ultraclean Technology Workshop (Tokyo: Ultraclean Society, 1997), 47­59.

Barry Gotlinsky, PhD, is vice president of microelectronics support in Pall's scientific and laboratory services department (Port Washington, NY). He has been involved in technical support of the microelectronics market for more than 15 years, publishing numerous articles on filtration and contamination control issues. He received his PhD in chemistry from the City University of New York. Gotlinsky is a senior member of the Institute of Environmental Sciences and Technology (IEST), and a member of the American Society for Metals International and the American Chemical Society. He has also chaired one of the Sematech test method task forces. (Gotlinsky can be reached at 516/484-3600 or barry_gotlinsky@pall.com.)

Joseph O'Sullivan, PhD, is technical director of microelectronics support at Pall's scientific and laboratory services department in Port Washington, NY, where he is responsible for technical support to the semiconductor industry. He received a BSc in chemistry and a PhD in physical chemistry from University College, Cork, Ireland. He has published several papers on filtration and contamination control, and he is a member of SEMI standard task forces. (O'Sullivan can be reached at 516/484-3600 or joe_o'sullivan@pall.com.)

Motonobu Horikoshi is a marketing manager for gas applications in microelectronics at Nihon Pall (Tokyo). From 1989 to 1992 he was a visiting researcher in the electronics department at Tohoku University (Sendai, Japan). Horikoshi is a member of the SEMI filter and purifier task forces as well as the Ultraclean Society and IEST. He received a BS in chemical engineering from Iwate University. (Horikoshi can be reached at motonobu_horikoshi@pall.com.)

Shinichi Babasaki works as a staff scientist for Nihon Pall's scientific and laboratory services in the gas application division in Tokyo. Before joining Pall he was responsible for APIMS operation and data interpretation. Babasaki is a member of the SEMI filter task force. He received a BS from Meiji University in Japan. (Babasaki can be reached at shinichi_babasaki@ pall.com.)